Flat Fold N95 Respirator

The Outdoor Research N95 Flat Fold Respirator is designed to provide respiratory protection for health care professionals during the Public Health Emergency. It is intended to reduce exposure to certain airborne particles and potentially infectious materials.

Made in the USA.

In stock
Only %1 left

Flat Fold N95 Respirator

$75.00
Sorry, none of our partners have this color and size in stock
 
Final Sale: Sorry, we do not accept returns or exchanges on masks, neck gaiters, or face coverings.
 
Important: Click here to access the User Manual. 
 
This product meets requirements of U.S. 42 CFR 84, and has been approved by NIOSH to provide N95 level of protection. This device does not protect against vapors or gasses. This device contains no components made with natural rubber latex.
 
NIOSH Approved N95 for Public Health Emergency: TC-84A-PH18
 
Listed on CDC NIOSH Certified Equipment List
 
FDA authorized for medical use under EUA
 
Final Sale: Sorry, we do not accept returns or exchanges on masks, neck gaiters, or face coverings.
 
Product Details
 
  • Head harness secured
  • Convenient fold flat design
  • Box count of 25

Available for Bulk Purchasing - Contact Us.

Full Berry Certificate available
 
Intended Use
 
Following CDC guidance, this respirator is intended to be used by healthcare workers for the duration of the Health Care Emergency and is authorized for use in healthcare setting under the Emergency Use Authorization by the FDA. This device meets CDC guidance for M.Tuberculosis exposure control. When worn properly, this respirator is intended to reduce user exposure to various airborne particles.
 
Outdoor Research N95 Flat Fold Respirator Protection Level:
NIOSH N95 approved, FDA EUA authorized
 
Tests Performed Test Method Performance
 
  • Barrier Test NaCl Particle Challenge NIOSH TEB-APR-STP-0059 ≥ 95%
  • Physical Test Inhalation resistance @ 85 LPM NIOSH TEB-APR-STP-0007 ≤ 35 mm H2
Instructions for Use
 
  • Consult federal, state and government agency regulations to ensure proper respirator use in the workplace. In the United States, employers must adhere to U.S. OSHA 29 CFR 1910.134 which includes a medical evaluation, training, andfit testing prior to respirator use in occupational settings. These user instructions are not a substitute for a written respirator training program which meets the aforementioned requirements. Fit testing must be performed on an individual basis, and a respirator should be selected to meet all the requirements for use, including compatibility with any other clothing or equipment which may interfere with fit. Fit testing should be performed at minimum annually by the employer using OSHA accepted protocols. Each time a respirator is worn, a fit assessment should be made by the user. This device is not intended to be used by those without proper training.
  • Thoroughly inspect the respirator mask prior to use. If components, including the filter material, the two headbands, the nose clip, or the headband attachments, are damaged or missing, do not use and dispose of properly. Damage may include missing components, tears or holes in the filter material, or other issues which noticeably have a negative effect on performance.
  • Immediately leave the contaminated area and seek help if dizziness, difficulty breathing, or other deleterious conditions arise.
  • This is a single use respirator. It may be used until it becomes difficult to breathe through, damaged, or is thought to be contaminated in any way. In a healthcare setting, it should be discarded after each examination or procedure. Given the Public Health Emergency PPE shortage, follow current government and facility guidance and regulations.
  • This product is not for use with beards, other facial hair or conditions which do not allow a proper seal between the respirator and the face. A fit check should be performed before every use. If a proper seal cannot be achieved, do not use.
  • Given current CDC guidance, it is recommended that this product is not for use by the general public in order to ensure supply for healthcare workers.
Fitting Instructions
 
  • Hold the respirator in your hand, with nose wire upward and headbands hanging below hand.
  • Place bottom of mask under chin, nose wire upward, and position over nose and mouth. Pull the upper strap to the top, back of head.
  • Pull the lower strap overhead to back of neck, secure below ears. Ensure that nothing is interrupting the seal between the respirator and the face.
  • With both hands cupped over the mask, press the nose wire with your fingertips to conform to the bridge of the nose. Ensure that the nose wire does not have a sharp bend not touching the nose, as this will result in an improper seal.
  • Complete a user seal check. Cover the mask with both hands and breathe sharply. If leakage is detected along the edge of the mask or nose wire, adjust nose wire, straps or repeat the above steps and perform another seal check. If leakage cannot be eliminated, do not enter hazardous environments and seek proper replacement protection.
*Respirator fit must be assessed on an individual basis, but this device has been found to fit smaller faces. Please reference the ‘instructions for use’ on the included insert prior to use.
 
Removal Instructions
 
Without touching the respirator filter media, remove the bottom strap from back head. Lift the top strap off form back, top of head. Be mindful not to touch face or respirator filter as hands may be contaminated. Dispose or store in accordance with current government and facility guidance and regulations.
 

 **The limited FFR approval will be effective until the declaration that circumstances exist justifying the authorization of the emergency use of personal respiratory protective devices during the COVID-19 outbreak is terminated under Section 564(b)(2) of the Act, or the EUA is revoked under Section 564(g) of the Act, or until such time that the approved configuration can no longer be maintained.

Specs


Product :
#283036

Fabric :

Features


Fabric Performance
N95 - Particulate Filtration

Design Features
Head harness secured
flat fold design
adjustable nose wire to conform to bridge of nose

Origin
USA

Rating and reviews

Q&A
 
Guarantee
 

The Infinite Guarantee®

Outdoor Research® gear is guaranteed to perform throughout the lifetime of the product. Get your gear back on track by filing a claim on our Warranty Page

Have a question? Problem? Other request? We’re here to help you find a solution.

Our customer service is waiting for your call at 855-967-8197, on weekdays Monday-Friday between 7am-5pm PST. If you prefer email, you can send your query to info@outdoorresearch.com

Thanks for getting in touch. We can’t wait to get you back outside with your gear.

SKU
283036

Hold on

Visiting from another country? Check out our international portal in order to check out with up to date currency and inventory

Find Your Country No thanks, Stay on this page